Philips Heartstart HS1 paediatric electrode pads
- SKU:
- M5072A
- UPC:
- 884838023758
- MPN:
- M5072A
- Weight:
- 0.35 KGS
Description
The Philips HeartStart HS1 Infant/Child SMART Pads Cartridge is the genuine paediatric electrode cartridge for the Philips HeartStart HS1 defibrillator.
Designed for infants and children under 8 years old and weighing less than 25 kg, the cartridge automatically tells the HS1 that paediatric treatment is required. The defibrillator then adjusts its voice instructions and reduces the nominal shock energy from 150 joules to 50 joules.
The pads are supplied ready inside a snap-in cartridge, helping make replacement and installation straightforward.
Why Choose Philips HeartStart HS1 Infant/Child SMART Pads?
- Genuine Philips replacement cartridge
- Designed specifically for the HeartStart HS1 AED
- For infants and children under 8 years old and under 25 kg
- Automatically recognised by the HS1
- Reduces nominal shock energy from 150 J to 50 J
- Adjusts voice and CPR instructions for paediatric treatment
- Snap-in cartridge design – quick and straightforward to replace
- At least 2-year use-by period from manufacture
- Clearly identified with a child/teddy bear symbol
Paediatric Use
The Philips HeartStart HS1 Infant/Child SMART Pads are intended for patients who are:
- 0–8 years old, and
- Under 25 kg
When the Infant/Child SMART Pads Cartridge is installed, the HeartStart HS1 automatically recognises it and changes its operation for paediatric treatment.
The AED provides paediatric-specific voice instructions and reduces the nominal defibrillation energy to 50 joules.
For patients over 8 years old or weighing 25 kg or more, use the compatible Philips HeartStart HS1 Adult SMART Pads Cartridge.
No Infant/Child Key Required
Unlike the Philips HeartStart FRx, the HS1 does not require a separate Infant/Child Key.
Paediatric operation is activated by installing the dedicated M5072A Infant/Child SMART Pads Cartridge.
Pad Replacement and Use-By Date
Philips states that the cartridge is labelled with a use-by date of at least two years from the date of manufacture.
The expiry date should be checked routinely as part of your AED inspection schedule. Replace the cartridge after use or when the printed use-by date is reached.
Compatibility
These pads are designed for:
- Philips HeartStart HS1 AED
They are not compatible with the Philips HeartStart FRx, which uses SMART Pads II with a separate Infant/Child Key.
Product Specifications
- Manufacturer: Philips
- Product: HeartStart HS1 Infant/Child SMART Pads Cartridge
- Compatibility: Philips HeartStart HS1
- Patient use: Infant and child
- Recommended patient: 0-8 years old and under 25 kg
- Nominal paediatric shock energy: 50 J
- Use-by period: At least 2 years from manufacture
- Active pad surface area: 85 cm² each
- Cable length: approximately 101.6 cm / 40 in
- Type: Disposable adhesive defibrillation electrodes
- Format: Snap-in cartridge
What's Included?
- 1 Philips HeartStart HS1 Infant/Child SMART Pads Cartridge containing one pair of paediatric electrodes.